Patient Monitor 12.1" Color TFT LCD Multi-Channel Display screen, #BMO200B

Write a Review
Your Price: $872.10
Part Number: BMO200B
Availability: In Stock. Free Shipping.

Choose Options



Features:

  • Multi-Parameter Patient Monitor
  • Flexible, Lightweight, Easy Operation
  • 12.1” TFT-LCD Color Screen with Multi-Channel Waveforms Display
  • Backlit buttons available 
  • Various language operating systems
  • Built-in detachable & rechargeable lithium battery
  • 2.5 hours of battery life
  • Support for Wireless or Wired networking
  • 3 level Audible and visual alarming, Dual alarm light for physiological and technical alarming
  • Easy to learn, easy to use, simplified menus and dedicated functions keys
  • Easy connection with the central monitoring system
  • 96 hours of data storage
  • Monitors end tidal CO2 and inspired CO2 accuracy at high respiration rates
  • Gas monitoring with cutting edge water filter tube

Fast & Stable Data Storage

  • 400 groups NIBP measurements
  • 72 hours Trend data and Trend graphs
  • 200 groups Alarm events review
  • 12 hours Wave forms review
  • Arrhythmia analysis and drug dose calculation

Standard Configuration:

  • ECG
  • RESP
  • NIBP
  • SpO2
  • PR
  • TEMP

Optional:

  • 2-IBP
  • EtCO2
  • Touchscreen
  • Built-in thermal printer

Standard parameters:3/5-Lead ECG, ECG, NIBP,  BMV SpO2, HR/PR, 2-RESP, 2-TEMP, Rechargeable Battery
Optional configuration:Built-in printer, BMV SpO2, Nellcor SpO2, Masimo SpO2, 2-IBP, ETCO2(mainstream or side),
WLAN accessory, Wall Mount, Moving cart
ECG 
Number of Leads:3 or 5 leads Lead View
Lead output:3 wires/5 wires ECG cable
User Selectable:I, II, III, aVR, aVL, aVF, V (5 Lead); I, II or III (3 lead)
Gain Selection:x1/4, x1/2, x1 and x2 Frequency Response
Diagnostic:0.05 to 90HZ
Monitor:0.5 to 35 HZ
Surgery:Surgery: 1-15HZ
Calibration Signal:1 (mV p-p)
Accuracy :ECG calibration: ± 1 mv Heart rate accuracy: ± 1%
ECG Signal Range:±8 m V (Vp-p)
ReviewAvailable
NIBP (Non-invasive Blood Pressure) 
Technique:Oscillometric during inflation range
Measurement type:Adult, pediatric, neonate
Measurement parameter:Systolic, Diastolic, Mean
Adult:40-270 mmHg
Pediatric:40-240 mmHg
Neonate:10-150 mmHg
Measurement cycle:<40 sec, typical
Cycles (Selectable):2, 3, 5,10,15, 30 min / 1, 2, 4hr
STAT model:5 minutes of continuous reading Max Allowable Cuff Pressure
Adult:300 mmHg
Pediatric:240 mmHg
Neonate:150 mmHg
Resolutions:1 mmHg
Transducer Accuracy :±2 mmHg or ±2% of reading
SpO2  
Display type:Waveform, data
Measurement range:0~100%
Resolution:1 BPM
Pulse rate range:30~250bpm
Accuracy:±1bpm
CO2 (option) 
Measurement range:0% ~ 10.0% (Carbon dioxide inhalation and carbon dioxide exhalation)
Accuracy:

±2mmHg (<5% Measured values)

10%(>5% Measured values)

Pulse Oximetry 
Range:0 to 100%
Resolution:1%
Accuracy:70% to 99% range ±2%,1% to 69% range ±5%
Bodymark:

•Over 144 bodymark patterns for all applications
•Support transducer mark

Method:Dual wavelength LED
Respiration Rate: 
Rate:Adult: 0 ~ 120 rpm / Neo/Ped 0 ~ 150 rpm
Resolution:1 rpm
Accuracy:± 2 breath/min
Heart (Pulse) Rate 
Range:Adult 15-300 bpm, Pediatric 15-350 bpm
Accuracy:±2bpm or ±3% whichever is greater
Trends 
Memory:96 hr at 30 second intervals for a NIBP reading every 5 minutes
Display :Trabular; Graphical